Interventional Cardiology or Urology Guidewire with Hydrophilic Coating

Type: Surgical Supplies Materials
Material: Nitinol
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: 3 Years
Group: Adult
Logo Printing: Accept Customized Item
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Rapidguide
Option
OEM/ODM
Transport Package
Paper Bag+Inner Box+Carton
Specification
0.035", 180cm/260cm
Trademark
Rapidguid
Origin
China

Product Description

Interventional Cardiology or Urology Guidewire with Hydrophilic Coating
The guide wire is designed to peripheral blood vessels intervention treatment, guiding and positioning catheter inserted into the blood vessels.
Interventional Cardiology or Urology Guidewire with Hydrophilic Coating



Interventional Cardiology or Urology Guidewire with Hydrophilic Coating
1. Advanced hydrophilic coating to provide lasting lubrication.
2. Soft atraumatic tip provides flexibility and minimizes trauma.
3. The NT core provides 1:1 torque control, perfect combination of support and maneuverability in tortuous anatomy.
4. Enhanced visualization for accurate positioning.
5. Complete range of specification to accommodate physician preference.

Interventional Cardiology or Urology Guidewire with Hydrophilic Coating

Overall of manufacturing
7.1 Production process
The guide wire mainly production process includes: electrochemical machining, extrusion, cutting, hydrophilic coating, Packaging sealing, EO sterilization. The detail information see MA-PFC-GW-002-A0< Production Flow Chart >.
7.1.1 Electrochemical Machining Process
We adopt electrochemical machining principle, the nickel and titanium core wire is grinding into a specified shape, avoiding the powder produced by the grinding of ordinary machinery. The electrochemical Machining process validation were performed, and edited < Electrochemical Machining SOP>.
7.1.2 Extrusion Process
The extrusion molding principle is used to wrap the plastic-clad layer tightly on the grinding core wire and realize the continuous extrusion.The extrusion process validation were performed, and edited < Extrusion Process SOP>.
7.1.3 Hydrophilic coating Process
The hydrophilic coating material is polyvinyl pyrrolidone (PVP), the hydrophilic coating solution was coated around the polymer jacket. The hydrophilic coating Process validation were performed, and edited < Hydrophilic coating Process SOP>.
7.1.4 Packaging sealing Process
The packaging sealing Process validation data see MA-CTF-001-15.
7.1.5 EO sterilization Process
The detail EO sterilization data see MA-CTF-001-14.
7.2 Quality control
7.2.1 Raw Materials Quality Control 
We have estambilished < Guide wire's Raw Materials Specification >, all the materials should be inspected by QC before been put in raw materials storage. If found rejects, then need to deel with < Nonconforming Product Control Procedure >.
7.2.2 In-process Control
We have estambilished < Guide wire's In-process Products' Specification >. Usually the operators carry out the self-check, and QC responsble for first article inspection and last article inspection. Sampling inspection taked by QC in manufacturering process.If found rejects, then need to deel with < Nonconforming Product Control Procedure >.
7.2.3 Final Quality Control
We also have estambilished < Guide wire's Final Product Specification >, all the final guide wire products should be inspected by QC before been put in finished warehouse. If found rejects, then need to deel with < Nonconforming Product Control Procedure >.



Interventional Cardiology or Urology Guidewire with Hydrophilic Coating
Diameter 0.014''(0.36mm)/0.018''(0.46mm)
0.021''(0.53mm)/0.025''(0.64mm)
0.032''(0.81mm)/0.035''(0.89mm)/0.038''(0.97mm)
Length 50cm//80cm/120cm/150cm/180cm/200cm/220cm/260cm/300cm
shape of distal end Angled/Straight/ Straight (with gold spring coil)
Hardness Normal/Hardened